The room sensors are used to provide reliable, accurate temperature readings in surface-mount room environments, Energy Management Control Systems, compatible with all the leading control systems.They feature a standard plastic ventilated enclosure.
Product Highlights:
Three low cost room temperature sensors to choose from.
High precision thermistor or RTD, accurate to 0.2C(+/-.36F).
The sensor measures temperature in stratified air such as the mixing sections of air handlers. The sensor has a standard 10k type 2 temperature-resistance curve compatible with all major control systems.
This sensor is used to measure the outside air temperature to allow the DDC system to coordinate the mechanical systems with actual building load conditions, enabling such strategies as free cooling, optimum start/stop, and supply temperature reset. The housing is made from PVC and stainless steel fittings which shield the probe from direct sunlight. There are three thermistor based models, and one RTD version to provide compatibility with the majority of DDC systems.
The temperature sensor is designed to measure outdoor air temperature in typical HVAC applications. Mounting is quick and easy using two screws and no electrical box. The thermistor is a well sealed stainless steel probe which is then inserted into a hard rubber PVC radiation shield. The cable is two meters long which allows terminating inside the building in an electrical enclosure or with flying leads. The cable can exit directly behind the probe and into the building through a hole, or it can exit vertically and run down the wall. A foam backing seals the hole in the wall if there is one and also serves to thermally insulate the probe from the wall. The probe is filled with thermal grease for quick response.
Bacnet Room Setpoint & Temp Display can be used in environment monitoring and controlling in industrial,commercial and other buildings,Modbus RS485/Bacnet MS/TP for direct digital reading on all models.
The Boiler stack temperature sensor and thermowell are designed to monitor the temperature of boiler stacks, steam lines and other applications where the temperature is above the operating range of typical HVAC thermistor type sensors. Maximum operating temperature of 300 Deg C (570 DegF).
This sensor is used to measure water temperature of heated or chilled water and other liquids found in the various mechanical systems of building. The sensor is especially intended for strapping to the outside of a pipe when there is no opportunity to install a well such as in a retrofit or additions to an existing system.The strap on probe is useful in applications such as monitoring batteries, transformers, generators, and generally any place where a complete assembly can not be mounted,Ice rink slabs and soil temperature are other applications.
The strap-on Insert sensor consists of a stainless steel sheath temperature sensor, thermal conducting compound, and an adjustable pipe bracket accessory. The stainless steel sheath temperature sensor is suitable for direct application to pipe surfaces for chilled or hot water measurement.
These thermowells are designed for mounting temperature sensors in pipes and tanks.The thermowells are designed to handle this stress while providing good thermal contact with the fluid.They also provide isolation, if the sensor needs to be serviced the system can remain in operation without having to drain the lines. The thermowells are machined from a single piece of bar stock, there are no welds as found on competing products.