The duct sensor is used to measure the supply and return air temperature in HVAC system. There are several sensor elements to choose from which guarantee compatibility with all popular DDC systems. There is a precision thermistor. The probes are epoxy sealed to prevent moisture from migrating into the probe. Field calibration is not generally required. The standard probe length is 12 inch. Custom probe lengths, wire types and sensor elements are available for large OEM projects. Ask about our plastics & metal manufacturing capabilities for custom housings as well.
Product Highlights:
Designed for Temperature sensing in an HVAC and Light Industrial Control applications
Precision interchangeability eliminates the necessity for individual circuit calibration
Able to produce custom sensors in small volume a standard sensor pricing
This Probe Temperature Sensor comes standard with a 15mm Stainless Steel Temperature Sensor. This sensor is a 10K Thermistor, with an industry standard Type 2 curve.Connected to the end of the Sensor is 2 UL2468 26/2CAWG 105°C Black Wires with tinned ends.
The strap-on Insert sensor consists of a stainless steel sheath temperature sensor, thermal conducting compound, and an adjustable pipe bracket accessory. The stainless steel sheath temperature sensor is suitable for direct application to pipe surfaces for chilled or hot water measurement.
The Boiler stack temperature sensor and thermowell are designed to monitor the temperature of boiler stacks, steam lines and other applications where the temperature is above the operating range of typical HVAC thermistor type sensors. Maximum operating temperature of 300 Deg C (570 DegF).
This sensor is used to measure water temperature of heated or chilled water and other liquids found in the various mechanical systems of building. The sensor is especially intended for strapping to the outside of a pipe when there is no opportunity to install a well such as in a retrofit or additions to an existing system.The strap on probe is useful in applications such as monitoring batteries, transformers, generators, and generally any place where a complete assembly can not be mounted,Ice rink slabs and soil temperature are other applications.
This sensor is used to measure the outside air temperature to allow the DDC system to coordinate the mechanical systems with actual building load conditions, enabling such strategies as free cooling, optimum start/stop, and supply temperature reset. The housing is made from PVC and stainless steel fittings which shield the probe from direct sunlight. There are three thermistor based models, and one RTD version to provide compatibility with the majority of DDC systems.
Bacnet Room Setpoint & Temp Display can be used in environment monitoring and controlling in industrial,commercial and other buildings,Modbus RS485/Bacnet MS/TP for direct digital reading on all models.
The sensor measures temperature in stratified air such as the mixing sections of air handlers. The sensor has a standard 10k type 2 temperature-resistance curve compatible with all major control systems.