The temperature sensor is designed to measure outdoor air temperature in typical HVAC applications. Mounting is quick and easy using two screws and no electrical box. The thermistor is a well sealed stainless steel probe which is then inserted into a hard rubber PVC radiation shield. The cable is two meters long which allows terminating inside the building in an electrical enclosure or with flying leads. The cable can exit directly behind the probe and into the building through a hole, or it can exit vertically and run down the wall. A foam backing seals the hole in the wall if there is one and also serves to thermally insulate the probe from the wall. The probe is filled with thermal grease for quick response.
We have designed this clip-on temperature sensor for use with refrigerant lines and copper tubing in hydronics applications. The sensor installs easily without drilling and reacts to temperature changes in seconds. Industry standard sensor elements are compatible with all major controls systems.
The tamper proof room temperature sensor with Torx security screws designed for use with building automation systems in commercial buildings, hospitals, museums or other facilities requiring accurate measurement of room temperature. This sensor can be directly mounted to drywall or an 11-10 electrical handy box.
This sensor is used to measure the outside air temperature to allow the DDC system to coordinate the mechanical systems with actual building load conditions, enabling such strategies as free cooling, optimum start/stop, and supply temperature reset. The housing is made from PVC and stainless steel fittings which shield the probe from direct sunlight. There are three thermistor based models, and one RTD version to provide compatibility with the majority of DDC systems.
The Boiler stack temperature sensor and thermowell are designed to monitor the temperature of boiler stacks, steam lines and other applications where the temperature is above the operating range of typical HVAC thermistor type sensors. Maximum operating temperature of 300 Deg C (570 DegF).
This sensor is used to measure water temperature of heated or chilled water and other liquids found in the various mechanical systems of building. The sensor is especially intended for strapping to the outside of a pipe when there is no opportunity to install a well such as in a retrofit or additions to an existing system.The strap on probe is useful in applications such as monitoring batteries, transformers, generators, and generally any place where a complete assembly can not be mounted,Ice rink slabs and soil temperature are other applications.
The sensor measures temperature in stratified air such as the mixing sections of air handlers. The sensor has a standard 10k type 2 temperature-resistance curve compatible with all major control systems.
Notice from Bravo Controls: We’re off for the local China National holiday from October 1st to October 8th 2025. Shipments will resume on the October. 9th.2025. Dismiss