The duct sensor is used to measure the supply and return air temperature in HVAC system. There are several sensor elements to choose from which guarantee compatibility with all popular DDC systems. There is a precision thermistor. The probes are epoxy sealed to prevent moisture from migrating into the probe. Field calibration is not generally required. The standard probe length is 12 inch. Custom probe lengths, wire types and sensor elements are available for large OEM projects. Ask about our plastics & metal manufacturing capabilities for custom housings as well.
Product Highlights:
Designed for Temperature sensing in an HVAC and Light Industrial Control applications
Precision interchangeability eliminates the necessity for individual circuit calibration
Able to produce custom sensors in small volume a standard sensor pricing
The BACnet Room Setpoint & Temperature Display is developed for use in industrial, commercial, and smart building environments where reliable environmental monitoring is required. Real-time temperature values and room setpoints are displayed through BACnet MS/TP or Modbus RS485 communication protocols.
Integration with building automation systems (BAS) and HVAC controllers is enabled through standardized communication support.
The strap-on Insert sensor consists of a stainless steel sheath temperature sensor, thermal conducting compound, and an adjustable pipe bracket accessory. The stainless steel sheath temperature sensor is suitable for direct application to pipe surfaces for chilled or hot water measurement.
We have designed this clip-on temperature sensor for use with refrigerant lines and copper tubing in hydronics applications. The sensor installs easily without drilling and reacts to temperature changes in seconds. Industry standard sensor elements are compatible with all major controls systems.
The Boiler stack temperature sensor and thermowell are designed to monitor the temperature of boiler stacks, steam lines and other applications where the temperature is above the operating range of typical HVAC thermistor type sensors. Maximum operating temperature of 300 Deg C (570 DegF).
The Over Molded Floor Heating Sensor delivers precise temperature monitoring, high durability, and reliable performance for residential and industrial floors
This sensor is used to measure the outside air temperature to allow the DDC system to coordinate the mechanical systems with actual building load conditions, enabling such strategies as free cooling, optimum start/stop, and supply temperature reset. The housing is made from PVC and stainless steel fittings which shield the probe from direct sunlight. There are three thermistor based models, and one RTD version to provide compatibility with the majority of DDC systems.
The sensor measures temperature in stratified air such as the mixing sections of air handlers. The sensor has a standard 10k type 2 temperature-resistance curve compatible with all major control systems.